1-D4720-001-14
OMD Mk6 junction box for 14 detectors with M20 glands
- Engine mounted to minimize cable length to the detectors
- Provides screw terminal connections for up to 14 OMD Mk6 detectors
- Connects directly to the OMD Mk6 control panel
- Includes the end of line termination for the detector communication connection
- A back-up alarm relay output provides a high oil mist level indication in the event of a communications failure with the control unit
Alternative products
Related products
At a glance
Product overview
The junction box is connected to the OMD Mk6 control panel by two cables, 24 VDC to power the detectors and a communication cable. Up to 14 OMD Mk6 detectors may be connected to the junction box minimizing the cable lengths to the detectors.
The control unit cables are connected via two M20 plastic glands, cable diameter 10 to 14 mm.
Metal glands included with the junction box provide easy connection of the detector cable screen to the junction box enclosure earth and maintain the IP65 rating of the unit.
An independent back-up alarm relay output provides a high oil mist level indication in the event of a communications failure with the control unit.
Details
- Engine mounted to minimize cable length to the detectors
- Provides screw terminal connections for up to 14 OMD Mk6 detectors
- Connects directly to the OMD Mk6 control panel
- Includes the end of line termination for the detector communication connection
- A back-up alarm relay output provides a high oil mist level indication in the event of a communications failure with the control unit
- Metal glands provide easy connection of the detector cable screen to the junction box enclosure earth
Technical specifications
| Electrical | ||
|---|---|---|
| Power supply type |
24 VDC
|
|
| Power consumption |
0.1 W
|
|
| Operating voltage |
24 VDC (-25% / +30%)
|
|
| Input | ||
|---|---|---|
| Input quantity |
2
|
|
| Input type and rating |
1 x RS485, 1 x 24 VDC, 4 A max.
|
|
| Output | ||
|---|---|---|
| Output quantity |
15
|
|
| Output type and rating |
14 x OMD Mk6 detector, 1 x volt-free change over relay rated at 30 VDC, 1 A
|
|
| Physical | ||
|---|---|---|
| Physical dimensions |
318 x 186 x 90 mm (L x W x D)
|
|
| Net weight |
2.7 kg
|
|
| Colour |
Aluminium
|
|
| Cable entries |
17
|
|
| Material |
Aluminium
|
|
| Environmental | ||
|---|---|---|
| Operating temperature |
0 to +70°C
|
|
| Storage temperature |
-20 to +60°C
|
|
| IP rating |
IP65
|
|
Downloads
All downloadsDatasheet
Technical documentation
If available, the downloads of the Certificates, Software & Firmware and Media are displayed in their default language.